NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000       NATIONWIDE FREE DELIVERY OVER R2000      
Sale!

Higrade H-C100E Softening Resin – 25 Liter Bag

Original price was: R1,359.50.Current price is: R1,087.50.

Product details

Higrade HGD H-C100E Softening Resin

Higrade HGD H-C100E Softening Resin is a strong acid cation exchange resin used to reduce calcium and magnesium hardness in water. Installed in a correctly sized water softener, it helps reduce hardness-related scale build-up in plumbing, geysers, heating equipment and appliances.

Supplied in the sodium form, the resin is regenerated using sodium chloride brine for repeated softening cycles.

  • Reduces calcium and magnesium hardness.
  • Helps protect equipment against hardness-related scaling.
  • Suitable for compatible domestic, commercial and industrial softeners.
  • Regenerates using suitable water-softener salt.
  • Supplied in a 25 Liter bag.

 

Resin media only. A compatible softening system, brine tank and regeneration salt are required separately.

Hard water contains dissolved calcium and magnesium that can contribute to scale deposits and soap scum. Higrade H-C100E treats this hardness through ion exchange: the resin captures calcium and magnesium ions and releases sodium ions into the water.

As the resin’s usable capacity is consumed, the softener must regenerate the media. Salt brine restores its sodium form, while the regeneration and rinsing cycles discharge the captured hardness minerals.

Key Benefits

  • Hardness reduction: Treats the dissolved minerals responsible for hard water.
  • Scale management: Helps limit further hardness-related deposits in downstream equipment.
  • Improved washing performance: Can reduce soap scum and the effects of hard water on cleaning.
  • Regenerable media: Supports repeated service cycles when correctly operated and maintained.

 

Typical Applications

  • Domestic point-of-entry water softeners.

  • Commercial water-softening systems.

  • Hardness reduction before reverse osmosis.
  • Industrial process-water pretreatment where softened water is required.
  • Replacement media for compatible existing water softeners.

 

Application suitability depends on the complete SANAS accredited water analysis, required flow rate and treatment target.

Softening and deionisation are different processes. In its sodium-form softening application, H-C100E exchanges hardness ions for sodium. It does not desalinate the water or provide the same treatment as mixed bed DI resin.

Parameter Specification
Brand Higrade / HGD
Product model H-C100E
Product category Water-softening ion exchange resin
Resin type Strong acid cation exchange resin
Polymer matrix Polystyrene crosslinked with divinylbenzene
Functional group Sulphonic acid
Supplied ionic form Sodium, Na⁺
Appearance Transparent spherical beads with a yellow tint
Moisture content 46–50% in sodium form
Bulk density Approximately 800–840 g/L
Principal treatment function Calcium and magnesium hardness reduction
Regeneration medium Sodium chloride brine
Pack size 25 L bag

System Sizing and Operating Requirements

A 25 Liter bag describes the volume of resin supplied. It does not specify the system’s flow rate or the number of liters that can be treated between regenerations.

Resin quantity, vessel diameter, bed depth, available backwash space and regeneration settings must be selected together. The required settings depend on incoming hardness, daily consumption, peak flow and the permitted hardness in the treated water.

The vessel, control valve, distributors and other components must also be suitable for the installation’s operating pressure and temperature.

Monitor treated-water hardness

Test hardness before and after the softener to confirm performance. Check treated water towards the end of the service cycle to identify hardness breakthrough and assess whether regeneration settings remain appropriate.

A TDS meter does not measure hardness and cannot confirm that the softener is working correctly.

Maintain the salt supply

Use suitable water-softener salt and inspect the brine tank regularly. Check for salt bridging, sediment accumulation and faults that prevent the system from drawing brine.

Salt consumption and regeneration frequency depend on the resin quantity, incoming hardness, water use and selected operating capacity.

Check the complete regeneration cycle

Confirm that the control valve completes its programmed backwash, brine draw and rinse stages. Backwashing alone does not restore exhausted softening capacity.

After installation or media replacement, commission and rinse the system according to the equipment instructions before returning it to service.

Protect the resin from fouling

Provide appropriate pretreatment where the water contains suspended solids, iron, manganese or other constituents that could foul the resin. Assess chlorine and other oxidants, as prolonged exposure can damage ion exchange media.

Use only cleaning and sanitising procedures confirmed as compatible with the resin and softener components.

Store and preserve correctly

Keep unused resin moist in clean, sealed packaging, protected from contamination and freezing. Do not allow the resin bed to dry out.

For prolonged shutdowns, follow an appropriate preservation and recommissioning procedure. Simply leaving a softener unused does not prevent microbiological growth.

Replace according to performance

Resin life varies with water quality, contaminant loading, regeneration effectiveness and operating conditions. Before replacing the media, check the salt supply, control valve, injector, flow rate and regeneration settings.

Replacement may be necessary where fouling, bead damage or capacity loss prevents satisfactory hardness reduction after correct servicing.

Shipped in 2 to 3 working days.

* Free Shipping does not include FRP Vessels, Filter Media Bags such as pH Fix, Drydan AFM, Drydan Glass Sand, Softening Resin, Carbon, Katalox, Brine Tanks and Salt. Additional charges will be charged extra for these products due to the weight and size. For shipping you will need to select the “Filter Media & FRP Shipping Charges” at the bottom of the shipping rates! Order will not be delivered if incorrect shipping rates are selected!

This product is sold with no warranty and/or guarantee, of whatsoever nature, unless the client can provide Osmotech (Pty) Ltd with a SANAS accredited laboratory water test report not older than 3 months from the date of testing, tested in accordance with SANS241 minimum recommendation for human consumption. Osmotech (Pty) Ltd will not be liable under any circumstances for consequential or incidental damages and/or losses, of whatsoever nature, unless a proper consultation procedure with Osmotech (PTY) Ltd has been followed.

Description

Higrade HGD H-C100E Softening Resin is replacement or initial-fill media for compatible water-softening systems. It provides targeted hardness treatment where calcium and magnesium contribute to scale deposits or interfere with the intended use of the water.

Correct selection involves more than choosing a bag quantity. Incoming hardness, peak flow, daily consumption and the required regeneration interval determine the resin volume and system configuration.

What is supplied

One 25 L bag of Higrade HGD H-C100E Softening Resin.

The pressure vessel, control valve, brine tank, salt, fittings and installation are supplied separately unless expressly included in a complete system package.

Performance and Limitations

  • Reduces calcium and magnesium hardness; it does not reduce overall TDS or produce deionised water.
  • Sodium-form softening increases the sodium content of the treated water.
  • Does not disinfect water or provide protection against bacteria and other microorganisms.
  • Does not replace sediment filtration, activated carbon, reverse osmosis or other treatment required by the water analysis.
  • Must not be selected as a general-purpose solution for iron, manganese or other borehole-water contaminants without assessing suitability.
  • Helps limit new hardness-scale formation; removal of existing deposits is not guaranteed.

 

Corrosive water

Water softening does not correct low pH or corrosive water conditions. Where the water has a negative Langelier Saturation Index or other indicators of corrosivity, the treatment plan must address these conditions before softening is selected.

Selecting the correct resin quantity

For borehole, river, rainwater or other variable water sources, Osmotech requires a SANAS-accredited laboratory analysis no older than six months before providing a treatment recommendation or quotation. Peak flow rate and daily water consumption are also required for system selection.

IMPORTANT TO NOTE

* For Borehole, Well Water, River Water and/or Dam Water, it is always advised to get the water tested trough as SANAS accredited water lab in accordance with SANS241 minimum recommendation for human consumption, before purchasing any water filtration equipment.

* The information and recommendations in this publication are based on data we believe to be reliable. They are offered in good faith, but do not imply any warranty or performance guarantee, as conditions and methods of use of the products are beyond our control. As such, Osmotech (Pty) Ltd makes no express or implied warranties of any kind with respect to this product, including but not limited to any implied warranty of merchantability or fitness for a particular purpose.

* The filter media listed on this product page do not remove or kill bacteria. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

*The filter media on this product page is not to be used on water with a Negative Langelier Saturation Index (-LSI).

Additional information

Weight 25 kg
Dimensions 40 × 60 × 10 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Higrade H-C100E Softening Resin – 25 Liter Bag